Airia

ContractorsProductsAccessories

Accessories

Weatherhoods

Ideal for HRV/ERV and Inline Fan applications

  • Maximized amount of free air space – 37 square inches.
  • Made of high density polyethylene for a durable, long life even in severe climates!
  • Incorporated screens to protect against the entry of animals and birds.
  • No moving parts eliminates freezing and sticking potential.
  • Hoods are easily removed for cleaning with no tools required.
  • Clearly labelled hoods for exhaust and intake.
  • Mounting collars and galvanized sleeve available
  • Available in 5” 6” and 7” sizes

Download documents


Techgrille

Fully adjustable ventilation grille

  • Cool white
  • Non-corrosive
  • Compression spring tab clips the grille into 4” 5” 6” or 8” round duct
  • No screws required
  • The center adjustment cone spins in and out, allowing for variable ventilation Capacity

Download documents


Kitchen Grille, Part #10-002

Hinged kitchen exhaust grille easily flips open for access to washable aluminum air filter. White.

Download documents


Bathroom Exhaust System, Part #98-CAF-BESKIT

The new BES is the perfect way to ventilate specific locations with a Clean Air Furnace. The BES allows you to exhaust multiple areas quietly and economically while also providing heat recovery through the Clean Air Furnace integrated heat recovery core.

Features:

  • BES Control Box
  • Quantum 4/5/6 COMBI Fan
  • Fan Speed Selection

Download documents


AccuFlow, Part #99-170

(no content)

Download documents


Lint Trap, Part #99-136

(no content)

Download documents


Inline Duct Heater

Occasionally it may be desirable to reheat the air being delivered from the HRV to the occupied space. This will not effect the performance of the HRV as the duct heater will be installed in the fresh air delivered to the house (from HRV).This configuration allows the HRV to recover the maximum amount of heat possible. The inline duct heater will then modulate the output required to reheat the air to the desired temperature.

The duct heater is equipped with the most advanced Electronic Modulating Controller (SCR) and Air Flow Sensor to minimize operating cost

  • Automatic reset thermal cut-out is a safety feature preventing overheating: will reset automatically after cool-off.
  • Manual reset thermal cut-out is an additional safety feature which prevents the frame from overheating.
  • Open coil elements made of the highest grade nickel-chrome resistance wire, they will not age or oxidize, thus assuring longer heater life.
  • Enclosure is made of corrosion resistant galvanized steel.
  • Air flow sensormodulates the heating capacity according to the quantity of air flowing through the heater.
  • Built-in electronic temperature controller and sensorproportionally modulates the heating load to match the exact capacity required minimizing operating cost.
  • Round collars simplifies the installation and considerably reduces field labour.

Available sizes: 7" diameter, 1KW, Part #99-160; 7" diameter, 2KW, Part #99-162; 6" diameter, 1KW, Part #99-163; 6" diameter, 2KW, Part #99-164; and Special Order, call for a quote.

Note: This type of system is generally only used when the HRV has a fully dedicated duct system

Download documents


Scrubber Air Treatment System

When Wood Smoke, Outside Odours, Dust, Pollen and Air Borne Pollutants are a problem:

Filtering the Air You Breathe

Filters are used to remove particles and odours from the air stream. The Scrubber air treatment system integrates a variety of filters into an effective air filtering system.

Pre-filter

The pre-filter is a white mesh polyester fibre. The purpose of this filter is to trap larger particles entering the Scrubber.

Pleated Media Filter

This large 50 mm (2”) filter is pleated to increase its surface area. It is a high performance, non woven cotton fabric reinforced with scrim and laminated to an expanded metal backup mesh.

Activated Carbon Filters

The activated carbon filters function as purifying adsorptive nets by trapping odours and impurities in the activated carbon's vast surface network where they remain embedded.

Available sizes: 6" post, Part #98-600; and 7" port, Part #98-600-7

Download documents


Summer Core, Part #68-250

Take advantage of free outdoor cooling with the Summer Core

The Summer Core is designed to be used in climates that can take advantage of the cooler summer night air.

During the hot summer days our homes can become uncomfortably warm. Now, by replacing your traditional heat exchange core with the “Summer Core”, you can bring in the cooler air from outside ...whenever it's available.

The unique design allows air to pass through the core without transferring heat, taking advantage of the cooler summer nights.

The Summer Core is easy to install.It simply slides in place of the existing heat exchange core.

Note :A 24 Hr .Programmable Timer could be used as an Optional Control when a Summer Core is installed

Download documents